Single piece, non welded construction Non coaxial fixing holes 600g/m2 galvanized coating Manufactured 10mm less to allow for notching/joist regularisation European Standard/ETA - BS EN845-1:2013+A1:2016 Test Standard - BS EN 846-8:2000 Galvanized Mild Steel DX51D+Z600 to EN10346:2015 with 600g/m2 Zinc Coating Projection - 75mm Shoe, 75mm Flange Height - 190mm 47mm Joist Width Material Gauge - 2.0mm Declared Loadbearing Capacity - 5kN SWL (SLS) Fire Rating - Euroclass A1 Fixing Type - Built in to masonry - No mechanical fixings required to wall. 3.75x30 square twisted nails to connect joist. Back of hanger must be tight against wall. Joists are to be cut square with a gap not exceeding 6mm from the rear of the hanger. A minimum 675mm of set masonry must be in place over support flange before loads are applied. Joist to be nailled through side gusset using 3.75x30mm square twisted nails. The underside of joists should be notched to provide a level surface for plasterboarding.

Masonry Joist Hanger 200mm x 47mm

SKU: 20001075